After preparing the temperature sensors and switching devices, the next step is to create the DSVT hardware module and configure its basic operating parameters.
DSVT operates through the Domoticz Python plugin system and also uses the Domoticz HTTP API to retrieve device data and perform certain control operations.
Correct connection settings are therefore essential for reliable operation.
Open the following Domoticz menu:
Setup → Hardware
For a new installation, select the DSVT plugin from the list of available hardware types.
If the DSVT hardware module already exists, open its configuration by editing the existing hardware device.
The following image shows the basic configuration fields of the DSVT hardware module.
The first four fields of the configuration interface contain the information required to connect to Domoticz.
If you use the Szélessáv SmartHome OpenWrt firmware, these parameters generally do not need to be modified.
By default, the firmware allows DSVT to access the Domoticz API through the local 127.0.0.1 address without requiring a separate username or password.
If DSVT and Domoticz are running on the same device, the default address is:
127.0.0.1
This is the localhost address, which refers to the device's own network interface.
If your system uses a different network configuration, enter the appropriate IP address.
The default HTTP port is:
8080
If Domoticz is accessible through another port, enter the actual port number.
If the local Domoticz API is accessible to DSVT without authentication, these fields can be left empty.
Other installations may require authentication because of their Domoticz security settings.
In that case, enter the appropriate username and password.
Important: local API access should only be permitted for genuinely trusted network addresses.
If DSVT cannot connect to Domoticz, check the Domoticz security settings.
Open:
Setup → Settings → Security
If necessary, allow the following local address in the Trusted Networks field:
127.0.0.1
When the plugin and Domoticz run on the same device, correctly configured local API access is generally sufficient.
Problems with local API access may prevent DSVT from starting or interfere with certain parts of its operation.
The remaining configuration fields allow you to specify the Domoticz devices used by DSVT.
Domoticz assigns a unique IDX identifier to every temperature sensor, switch, and other device.
DSVT uses these identifiers to recognise and control the corresponding sensors and equipment.
The configuration fields may contain different groups of devices, including:
In the DSVT hardware parameters, device identifiers are associated with specific keys and parameter groups.
Some fields allow multiple device IDX values to be entered, using the required separators.
The exact format depends on the requirements of the particular parameter group.
Important: the meaning and order of the configuration keys, as well as the required separators, must be preserved. Incorrect formatting or invalid IDX values may result in incorrect device assignments or plugin startup errors.
For this reason, using DSVT's dedicated HTML configuration interface is recommended instead of editing these fields manually.
Device identifiers can be checked in the Domoticz device list.
Open:
Setup → Devices
This list contains the sensors, switches, and other devices added to Domoticz.
The IDX identifier can be found in the device list or in the details of the corresponding device.
In some Domoticz interfaces, the identifier may also be accessible through the three-dot menu in the upper-right corner of a device or through its editing window.
The IDX may not be visible on every device tile displayed on the main Domoticz dashboard.
When checking an identifier, make sure you select the correct device, especially if several sensors or switches have similar names.
The DSVT hardware settings include an Operating parameters field, which must contain a valid value even during the initial installation.
The default setting is:
0,5,15,0,None
This parameter sequence contains essential plugin operating settings, including logging and timing parameters.
For the initial installation, retaining the default value is recommended.
Only modify these operating parameters if you understand the meaning of each value and the possible consequences of changing it.
DSVT includes a dedicated HTML-based configuration interface that simplifies device assignments and control parameter settings.
After creating the hardware module, detailed configuration can be performed through the Domoticz Custom menu.
Open:
Custom → HTML setup!
The configuration interface provides settings for:
The interface allows devices to be selected without manually entering every IDX identifier.
This reduces the risk of incorrect device identifiers and improperly formatted configuration fields.
For a new DSVT installation, the following sequence is recommended:
Following this sequence simplifies the initial installation and helps reduce problems caused by incorrectly configured hardware parameters.
After saving the configuration, verify that DSVT correctly recognises the assigned devices.
Pay particular attention to:
If DSVT fails to start or a device does not operate correctly, check the Domoticz log first.
Incorrect IDX identifiers, invalid configuration fields, and local API access problems can often be identified through log messages.
When configuring DSVT control parameters, first verify the Domoticz connection settings and mandatory operating parameters.
When using the Szélessáv SmartHome OpenWrt firmware, the default local connection settings can generally be used without modification.
Detailed device assignments are based on Domoticz IDX identifiers, which can be entered in the appropriate hardware configuration fields or selected through DSVT's dedicated HTML interface.
Using the HTML configuration interface is recommended because it makes configuring DSVT sensors, switching devices, and control parameters simpler and more transparent.