Periodic Anti-Seizure Exercise for Pumps and Motorized Valves

Pumps and motorized valves that remain unused for long periods can sometimes become difficult to move or may even seize. This is especially relevant in seasonally operated systems, for example when a heating system remains unused for several months during summer.

The purpose of the periodic exercise function is to automatically operate these devices for a short time at regular intervals, helping to reduce the risk of sticking or seizing caused by long periods of inactivity.

Periodic exercise settings for pumps and motorized valves

How does it work?

The function allows you to configure the system to automatically switch on selected devices once a week on a chosen day at a specified time.

You can configure:

After the configured operating time has elapsed, the system automatically switches the devices off again.

Important: minimum operating time

The actual operating time of the periodic exercise function cannot be shorter than the configured DSVT update cycle.

The default update cycle is 5 minutes. This means that if you configure an exercise duration shorter than this, the device will still remain switched on for at least one complete update cycle.

For example, with the default 5-minute update cycle, setting the exercise duration to 60 seconds will still result in an actual operating time of at least 5 minutes.

If you change the update cycle to a different value, the minimum operating time of the periodic exercise function changes accordingly.

What can it be used for?

The function is primarily useful for devices that may remain inactive for extended periods during normal operation.

Typical examples include:

For example, a circulation pump used only for heating may remain completely inactive for several months during summer. With periodic exercise enabled, the system can automatically run the pump for a short time every week, preventing it from remaining completely stationary throughout the entire off-season.

Weekly automatic operation

This function is not intended for continuous control. It is a preventive maintenance feature designed to operate selected devices briefly at regular intervals. The selected devices run at the configured day and time for the specified duration, but always for at least one complete update cycle.

Example

The system can, for example, be configured to:

  • run every Sunday,
  • start at 12:00,
  • switch on the selected pumps and motorized valves,
  • and keep them active for 10 minutes.

After the configured time has elapsed, the devices are automatically switched off and no further action is taken until the next scheduled weekly cycle.

If, for example, you set the duration to 1 minute while the DSVT update cycle is 5 minutes, the devices will actually remain switched on for at least 5 minutes.

Why is it useful?

The mechanical parts of pumps and valves that remain stationary for long periods may become harder to move due to scale, deposits, sticking seals, or simply prolonged inactivity.

Periodic exercise does not replace regular maintenance, but it provides a simple way to reduce the chance that a device will fail to start when it is needed again after a long period of inactivity.

The function operates automatically, so there is no need to manually run rarely used devices during the off-season.