Infrared Air Conditioner Control

DSVT allows air conditioners operated by infrared remote controls to be integrated into its 12-zone heating and cooling system.

Control is provided through a device running Tasmota firmware and equipped with an infrared transmitter. The device receives commands from DSVT over the local network.

Tasmota's IRHVAC function supports infrared control protocols from numerous air conditioner manufacturers, allowing compatible units to be controlled without using their original remote controls.

Compatibility depends on the IRHVAC protocols available in the Tasmota firmware and the specific air conditioner model.

Unlike conventional Domoticz devices, infrared-controlled air conditioners do not require a separate Domoticz device identifier (idx). DSVT sends control commands directly to the Tasmota device's network address.

1. How Infrared Air Conditioner Control Works

DSVT determines which commands to send to each air conditioner according to the heating or cooling demand of its assigned zone.

Air conditioners participate in the system's temperature regulation in a similar way to conventional heating and cooling zone valves.

When a zone requires heating or cooling, DSVT sends an infrared control command using the parameters configured for that zone.

The command can include the following parameters:

Control is performed through the Tasmota IRHVAC command.

2. Configuring Air Conditioners for Individual Zones

Air conditioners are configured through the DSVT HTML setup interface.

Each of the 12 zones can have separate air conditioner settings for heating and cooling.

This allows different air conditioners or different configurations to be used within the same zone, depending on whether the system is operating in heating or cooling mode.

The main configuration parameters include:

Settings can be stored independently for each zone, allowing the system to control compatible air conditioners from different manufacturers using different infrared protocols.

3. The Tasmota Infrared Controller

DSVT sends IRHVAC commands through the HTTP interface of the Tasmota device.

The infrared controller must be accessible over the network from the device running Domoticz.

The Tasmota device must run firmware that includes the required infrared HVAC functions and supports the selected air conditioner protocol.

The infrared transmitter should be positioned so that its signal can reliably reach the air conditioner's infrared receiver.

Infrared communication is generally one-way. Therefore, sending a command does not, by itself, allow DSVT to determine whether the air conditioner has actually received and executed it.

4. Automatic Heating Control

During heating operation, DSVT determines heating demand from the measured zone temperatures and the configured heating targets.

When a zone requires heating, the system sends a power-on command to the configured air conditioner using Heat mode.

The command includes the current heating target temperature and the configured fan and airflow direction settings.

When heating demand ends, DSVT can either switch the air conditioner off or leave it running, depending on the configuration.

The latter option can be useful for air conditioners where the internal temperature controller should maintain the room temperature rather than repeatedly switching the entire unit on and off.

5. Automatic Cooling Control

During cooling operation, DSVT works similarly, but determines cooling demand from the cooling target temperatures and switching thresholds of each zone.

When cooling is required, the system sends an infrared command using Cool mode.

The command includes the current cooling target temperature and the separately configured fan and airflow direction settings.

When the room reaches the cooling switching threshold, the system adjusts air conditioner operation according to the selected configuration.

Heating and cooling configurations are independent. Therefore, different fan and airflow direction settings can be used for the same air conditioner in heating and cooling modes.

6. Dynamic Target Temperature Control

DSVT uses the currently calculated zone target temperatures when controlling air conditioners.

As a result, the temperature sent to an air conditioner can reflect adjustments applied by the zone control system.

These adjustments may originate from:

If the current zone target temperature changes, DSVT can send a new IRHVAC command containing the updated target.

Important: DSVT does not directly control the air conditioner's internal temperature sensor. It sends the desired target temperature, which is then used by the air conditioner's own control system.

7. Presence-Based Air Conditioner Control

DSVT supports adjusting air conditioner operation according to presence information.

Presence-dependent behaviour can be configured separately for heating and cooling air conditioner settings in each zone.

This allows the system to apply power-on or power-off commands according to the central presence state.

For example, certain air conditioners can be configured to respond to occupancy information while other zones use different operating settings.

Presence-based air conditioner control can be used together with DSVT's general presence management functions.

8. Operation When the Target Temperature Is Reached

DSVT provides an option to prevent the air conditioner from being switched off automatically whenever the zone's heating or cooling demand ends.

This setting allows two operating strategies:

This option can be particularly useful for inverter air conditioners whose internal capacity modulation can adapt to changing heating or cooling demand.

The selected strategy should be compatible with the air conditioner's manufacturer requirements and the intended control method.

9. Automatic Infrared Command Resending

One characteristic of infrared control is that the air conditioner generally does not report its actual operating state back to the Tasmota controller.

Consequently, the command previously sent by DSVT may no longer match the air conditioner's actual state.

This may happen because of:

To address this limitation, DSVT provides an optional IR command resend function.

The resend frequency can be configured using a Domoticz selector switch.

The available settings are:

For example, if the DSVT update interval is 5 minutes and the air conditioner control function runs during every update, a setting of 2x may result in commands being resent approximately every 10 minutes, 5x approximately every 25 minutes, and 10x approximately every 50 minutes.

The actual interval depends on how frequently the control function is executed.

Handling New or Modified Commands

DSVT compares the currently generated IRHVAC command with the command previously sent.

If the command has changed, the system sends the new command immediately and resets the resend counter associated with that zone.

If the command remains unchanged, it is resent only when the configured number of control cycles has been reached.

Heating and cooling commands are tracked separately for each zone, so their resend counters operate independently.

This approach can reduce unnecessary network traffic and infrared transmissions while allowing the desired operating state to be periodically reinforced.

10. Network and Compatibility Requirements

Reliable communication between DSVT and the Tasmota infrared controller requires the following:

If the Tasmota controller is unreachable, DSVT cannot execute the requested air conditioner command.

Successful HTTP command transmission does not necessarily confirm that the air conditioner has received and executed the infrared instruction.

The air conditioner's built-in operating limits and safety protections remain applicable.

11. Summary

DSVT's Tasmota-based infrared air conditioner control allows compatible air conditioners to be integrated into a multi-zone heating and cooling system.

Air conditioners can be configured individually for each zone, with separate heating and cooling settings. Control is based on the current temperature demand and target temperature of the respective zone.

Fan speed, airflow direction, presence-based operation, and the power-off strategy applied when the target temperature is reached can all be configured independently.

Optional infrared command resending can help restore the intended operating state when the air conditioner's actual state changes because of external intervention.

When correctly configured, infrared air conditioner control allows conventional infrared remote-controlled air conditioners to participate in DSVT's centralised, zone-based heating and cooling management.

DSVT – Documentation and Guides

Browse installation instructions, configuration steps and detailed explanations of the control functions.

Heating, Cooling, DHW and Buffer Control – Overview

Overview and principles

Operational logic and operating modes

Intelligent control algorithms

Actuating devices and auxiliary controls

Installation and configuration

Usage and documentation

Version history