DSVT allows heating, cooling, and domestic hot water (DHW) operation to be automatically adjusted according to building occupancy.
The control system uses Normal and Economy operating modes, each with separately configurable target temperatures.
Users can switch between these modes manually, according to a predefined schedule, or automatically through presence detection.
This makes it possible to maintain the desired comfort level when the building is occupied while reducing unnecessary energy consumption during periods of absence.
DSVT presence-based control can automatically change the heating and cooling operating mode according to whether registered occupants are present or absent.
Presence can be determined, for example, by monitoring mobile phones or other network devices connected to the building's Wi-Fi network.
A properly configured presence monitoring system provides DSVT with information about whether any registered occupants are currently present.
When presence is detected, heating and cooling control switches to Normal mode.
The controller then applies the configured normal heating or cooling target temperatures for the individual zones.
When no presence is detected, heating and cooling control switches to Economy mode.
The economy target temperatures configured for the individual zones are then applied.
During heating, these temperatures are generally lower than normal target temperatures. During cooling, economy target temperatures are generally higher.
Important: presence detection controls operating mode changes only when the corresponding presence-based control function is enabled and valid presence information is available.
DSVT provides a separate switch for enabling presence-based heating and cooling control.
The switch has two operating states:
The presence-based control switch can also be managed using Domoticz scheduling functions.
This allows automatic presence-based control to be enabled only on selected days or during specified periods.
If DSVT previously switched the heating and cooling system to Economy mode because absence was detected, disabling presence-based control restores Normal mode.
However, if the operating mode was changed manually or by another automation rather than by presence-based control, disabling the presence function does not necessarily modify that setting.
This helps prevent presence control from unnecessarily overriding operating modes configured by other methods.
DSVT displays the current status of heating and cooling presence detection through a separate information device.
The status indication may include:
This status information allows users to verify presence monitoring operation through the Domoticz interface.
Consider a building that is used regularly during weekdays but is occupied only occasionally at weekends.
The following schedule can be configured:
When the occupants leave the building on Friday, DSVT can switch to Economy mode after their absence is detected.
If someone returns during the weekend, the controller automatically restores Normal mode when presence is detected.
At 16:00 on Sunday, the schedule disables presence-based control. If the system was previously placed in Economy mode by presence detection, DSVT restores Normal operation.
In this way, scheduling and presence detection complement each other without requiring manual intervention.
DSVT provides separate Normal and Economy heating and cooling target temperatures for every configured zone.
These values can also be adjusted independently using Domoticz scheduling functions.
For example:
Scheduled target temperature adjustments and switching between Normal and Economy modes are two separate control functions.
The first changes the configured target temperature of a particular zone. The second determines whether the system uses that zone's Normal or Economy target temperature.
If presence detection is unavailable or not required, switching between Normal and Economy modes can be handled entirely through conventional scheduling.
This is particularly suitable for buildings with relatively predictable occupancy patterns.
For example:
These times can be freely adjusted according to actual occupancy patterns and individual requirements.
In systems with high thermal inertia, it is important to remember that increasing or decreasing room temperature may take considerable time.
For example, with underfloor heating, excessive night-time temperature reduction may not provide significant energy savings and can result in slower heating the following morning.
DSVT also provides separate Normal and Economy operating modes for domestic hot water (DHW) production.
DHW control has its own presence detection switch, which can be enabled independently of heating and cooling presence control.
DHW control switches to Normal mode and uses the configured normal DHW target temperature.
DHW control switches to Economy mode and applies the corresponding economy target temperature.
The DHW presence-based control switch can also be scheduled through Domoticz.
If presence-based control previously activated DHW Economy mode, disabling the function can restore Normal operation.
Important: hygiene and Legionella risk management must be considered when configuring the DHW Economy target temperature. Energy efficiency must not compromise safe domestic hot water operation.
The effectiveness of presence-based control is strongly influenced by the thermal inertia of the building and its heating and cooling system.
In low-inertia systems, switching between Normal and Economy modes can produce relatively rapid temperature changes.
Examples include appropriately sized radiator systems and fast-response air conditioning units.
In high-inertia systems, temperature adjustments take considerably longer to become noticeable.
For example, underfloor heating embedded in a thick concrete layer stores substantial amounts of thermal energy. Consequently, changes to the target temperature are reflected in room temperatures only after a delay.
In these installations, it may be preferable to use smaller differences between Normal and Economy target temperatures and consider the building's expected occupancy in advance.
Appropriate use of Normal and Economy modes can reduce heating and cooling energy demand.
During heating, reducing the indoor target temperature generally decreases building heat loss because the temperature difference between indoor and outdoor environments becomes smaller.
However, the amount of energy saved is not constant.
It depends on factors including:
Therefore, no single percentage saving per 1°C reduction in target temperature can be reliably applied to every building.
Nevertheless, properly configured scheduling and presence-based control can help ensure that heating and cooling are provided only when required and at an appropriate level.
DSVT presence-based and scheduled control allows automatic selection between Normal and Economy operating modes.
Presence-based control for heating and cooling and for DHW can be enabled and scheduled independently.
Target temperatures can also be scheduled separately for individual zones, allowing the system to adapt not only to overall building occupancy but also to the usage patterns of individual rooms.
Properly configured presence detection, scheduling, and target temperatures can help maintain comfort, reduce unnecessary energy consumption, and improve the cost-effectiveness of heating and cooling operation.